Mengyan Wang, Lujia Han, Zengling Yang & Xian Liu

Species discrimination of terrestrial processed animal proteins by laser-induced breakdown spectroscopy (LIBS) based on elemental characteristics

(Volume 23 (2019) — Numéro 3)
Article
Open Access

Attached document(s)

Annexes

Editor's Notes

Received 12 September 2018, accepted 7 May 2019, available online 4 June 2019.

This article is distributed under the terms and conditions of the CC-BY License (http://creativecommons.org/licenses/by/4.0)

Résumé

Discrimination d’espèces de protéines animales terrestres transformées par spectroscopie de dégradation induite par laser (LIBS) basée sur les caractéristiques élémentaires

Description du sujet. Cette recherche présente une nouvelle approche pour déterminer la composition spécifique de protéines animales transformées (PAT) terrestres en utilisant la spectroscopie de décomposition induite par laser (LIBS) comme technique alternative pour déterminer la sécurité des aliments pour animaux.

Objectifs. Explorer la corrélation entre les résultats LIBS et la composition élémentaire. Évaluer le potentiel des méthodes spectroscopiques de LIBS pour la discrimination des espèces animales constitutives de PAT terrestres.

Méthode. Un total de 42 échantillons fiables de PAT terrestres d'origine ovine, bovine, porcine et avicole ont été analysés et les spectres LIBS ont été recueillis de façon innovante à partir d'une fraction osseuse séparée. Des modèles d'analyse discriminante (PLS-DA) des moindres carrés partiels ont été exécutés sur le jeu de données.

Résultats. Des différences significatives ont été observées dans les compositions d'éléments (carbone, azote, hydrogène, calcium, sodium, potassium, magnésium, zinc, strontium et baryum, < 0,05) de PAT terrestres provenant de différentes sources, ce qui indique un fort potentiel de discrimination des espèces. On a découvert des caractéristiques spectrales de LIBS marquées (21 variables) liées à six éléments (calcium, sodium, magnésium, zinc, strontium et baryum) pour différentes espèces d'échantillons de PAT terrestres. Les PAT des quatre espèces testées pourraient être bien classées avec une sensibilité et une spécificité élevées (> 0,90), de même que les PAT de ruminants et de non-ruminants pourraient être soigneusement discriminés. L’analyse discriminante décèle à 95 % une adultération à 10 %-40 % de ruminants dans des PAT terrestres.

Conclusions. Cette étude démontre que la LIBS peut mettre en évidence la composition élémentaire de différentes sortes de PAT terrestres et s’avère être une méthode prometteuse pour identifier les différentes espèces animales ou les groupes animaux (ruminants/non-ruminants) constitutifs de PAT terrestres.

Mots-clés : spectroscopie, élément chimique, farine d'os, discrimination, aliment pour animaux, adultération

Abstract

Description of the subject. This research presents a novel approach for species discrimination of terrestrial processed animal proteins (PAP) using laser-induced breakdown spectroscopy (LIBS) as an alternative technique for determining feed safety.

Objectives. To explore the correlation between LIBS results and elemental composition. To assess the potential of LIBS spectroscopic methods for species discrimination of terrestrial PAP.

Method. A total of 42 reliable terrestrial PAP samples of ovine, bovine, porcine, and poultry origin were analyzed and LIBS spectra were innovatively collected from the separated bone fraction. Partial least squares-discriminant analysis (PLS-DA) models were performed on the dataset.

Results. Significant differences were found in the element compositions (carbon, nitrogen, hydrogen, calcium, sodium, potassium, magnesium, zinc, strontium and barium, < 0.05) of PAP from different sources, which indicated a high potential for species discrimination. High-marked LIBS spectral characteristics (21 variables) related to six elements (calcium, sodium, magnesium, zinc, strontium and barium) for different species of terrestrial PAP samples were found out. PAP from the four tested species could be well classified with high sensitivity and specificity (> 0.90), while the ruminant and non-ruminant PAP could be thoroughly discriminated. For the discriminant analysis of ruminant-derived components in terrestrial PAPs, the detection of 10%-40% adulteration can be achieved and the correct rate is about 95%.

Conclusions. This study demonstrates that LIBS can mostly exhibit the elemental composition of different terrestrial PAP, and can be a promising method for discriminating the different animal species or animal groups (ruminant/non-ruminant) involved in terrestrial PAPs.

Keywords : spectroscopy, elements, bone meal, discrimination, feeds, adulteration

1. Introduction

1With the rapid development of animal husbandry, the quality and safety of animal feed products has become much more important. Processed animal proteins (PAP) have been recognized as a valuable source of protein for animal nutrition (Lecrenier et al., 2016). However, due to the risk of bovine spongiform encephalopathy (BSE), PAP used in animal feed has been subjected to close scrutiny. Aiming at the feed safety or even human health, it is essential to identify the species of animal derived ingredients in feedstuff (Gao et al., 2018).

2There are two stages for the worldwide research on the detection of PAP. During the first stage, meat and bone meal were totally prohibited as feed ingredients for all animals (EC/88/98, EC/126/2003, EC/152/2009), while light microscopy was the only official method. It can accurately detect the PAP in feedstuffs, but it is difficult to further determine the species. In 2013, the ban on non-ruminant PAP in fish feed was repealed (EC/51/2013), marking the entrance into the second stage. To implement this stage, there was an urgent need for species-specific methods for PAP detection. Therefore, polymerase chain reaction (PCR) was introduced as another official method, which can test the animal species based on specific regions of DNA strands. However, both of the officially accepted methods require tedious procedures, countless hours of analysis and technical expertise, which are less convenient for routine testing of the large quantities present in the feed trade (Fumière et al., 2009; Tena et al., 2014; Gao et al., 2017). Effective methods are still worth probing for species discrimination of PAP.

3Studies have shown the presence of various elements in PAP including carbon (C), hydrogen (H), oxygen (O), nitrogen (N), calcium (Ca), phosphorus (P), sodium (Na), magnesium (Mg), potassium (K), iron (Fe), zinc (Zn) (Cascarosa et al., 2012). Studies of meat quality show that elemental composition can vary depending on the animal species (Georgievskii et al., 1981; Bodwell & Anderson, 1986). However, the elemental differences in different species of animal bones are not consistent with those of meat (Bilge et al., 2016b; Yajie et al., 2017). Therefore, the complexity of PAP to be analyzed may create misinterpretations. For this reason, elemental studies focused on the bone fraction may be a more feasible choice, since the officially accepted microscopic method for PAP detection is also focused on bone fraction. Laser-induced breakdown spectroscopy (LIBS), also known as laser-induced plasma spectroscopy (LIPS), is a laser-based optical spectroscopy technique used to detect atomic, ionic and simple molecular emission signals of elements (Miziolek et al., 2006). It is simultaneously sensitive to all elements and requires minimal or no sample preparation. Coupled with multivariate analyses, LIBS has been widely applied for identification and classification purposes, such as for geomaterial classification (Sirven et al., 2007; Gottfried et al., 2009; Forni et al., 2013; Tian et al., 2014; Yu et al., 2016), detection of malignant tissues (Kaiser et al., 2012; Oztoprak et al., 2012), and discrimination of food species (Bilge et al., 2016a; Bilge et al., 2016b; Moncayo et al., 2016). However, studies on species discrimination of PAP by LIBS based on elemental characteristics remain scarce.

4The objectives of this study were to explore the differences of elemental composition between different species of terrestrial PAP and to reveal the correlation between LIBS and element characteristics. LIBS spectra were innovatively collected from the separated bone fraction of terrestrial PAP, and high-marked spectral characteristics related to element composition for different species were studied. Partial least squares-discriminant analysis (PLS-DA) models were further established on the dataset to assess the potential of LIBS spectroscopic methods for species discrimination of terrestrial PAP.

2. Materials and methods

2.1. Sample preparation and bone fraction extraction

5A total of 42 terrestrial PAP samples (eight ovine, ten bovine, fourteen porcine, and ten poultry) were collected for this study. Half of the samples were supplied by the national feed quality control center of China, which were obtained from the industrial retailers and producers from eight provinces in China. The rest were derived from fresh bones bought from local butchers’ and were self-manufactured by an industrial process (Ockerman & Hansen, 1999). All the samples were ground to 0.5 mm using an ultracentrifugal mill (ZM200 Retsch, Germany) that was previously decontaminated with DNA erase. To separate and concentrate the bone fraction, PAP samples were sedimented using tetrachloroethylene according EU regulation EC/51/2013 for the detection of processed animal particles via microscopy. What we call the “bone fraction” consists in the aggregation of the isolated bone particles. All samples were stored in a fridge at 4 °C for preservation.

6For the discrimination of adulterated samples, pure ruminant PAP were added into non-ruminant samples in accurate weighted proportions from 1 to 40% (w/w, 1%, 2%, 5%, 10%, 15%, 20%, 25%, 30%, 35%, 40%) and total 60 blended samples (six samples per level) were prepared. These powders are thoroughly mixed at room temperature and atmospheric pressure. Then the bone fraction was extracted from mixed PAP.

2.2. Elemental determination

7All analytical determinations were performed in duplicate, and the recorded result was the average. Carbon (C), hydrogen (H), oxygen (O), nitrogen (N), and sulphur (S) were determined by placing the bone fraction in an Elementar Vario EL II (Vario Macro, Germany). For the mineral content determination, dried samples of the bone fraction of PAP of different animal species were digested in an Ethos Touch Control microwave digestion system (Milestore, Italy). The contents of calcium (Ca), phosphorus (P), sodium (Na), magnesium (Mg), potassium (K), iron (Fe), zinc (Zn), strontium (Sr), barium (Ba), and gadolinium (Gd) in the digested samples were determined using inductively coupled plasma mass spectroscopy (Agilent 7500, USA) with for each a single element standard solution at a concentration of 1,000 ppm (Chemical Metrology & Analytical Science Division, China).

2.3. LIBS instrumentation and spectral analysis

8The bone fraction from each PAP sample was placed in an aluminium cover that had a loading size of ∅ 30 mm × 7 mm, and then were tableted at 20 t of pressure. A commercial LIBS system (ChemReveal™-3764, TSI, USA) was used for the spectral analysis. The laser beam from a Q-switched Nd: YAG laser operating at 1,064 nm was used to create the plasma on the surface of the tablets of the bone fraction. The best signal-to-background ratio was achieved at an 80-mJ pulse energy with a repetition rate of 2 Hz and a gate delay of 1 μs. The wavelength range used was approximately 190 to 950 nm. To minimize the influence of sample heterogeneity and laser energy fluctuations, 126 shots (14 × 9) with a step size of 1.5 mm were performed on each sample. The time required to perform an analysis of each sample is less than 5 min. ChemLytics™ software was used to obtain the average spectra and search spectral peaks.

2.4. Statistical analysis and multivariate evaluation

9Each element content was statistically compared using one-way ANOVA in the SPSS 20.0 program (SPSS, Inc., USA). A confidence level was set at 95% (p < 0.05). All data processing and modelling in the multivariate data analysis were conducted on Matlab 2012a (The Mathworks, Inc., USA) using the PLS Toolbox 3.5 (Eigenvector Research, Inc., Manson WA).

10The element profile and LIBS spectra of several bone fractions were investigated based on principal component analysis (PCA). Partial least squares-discriminant (PLS-DA) were further applied to the dataset of whole LIBS spectra and the selected spectra, respectively. At first, all data were divided into four categories according to animal species. The applied data pretreatments were standard normal variate (SNV) and mean centre (MC). Then PLS-DA discrimination models were established based on LIBS spectra via internal cross-validation (leave one out). In addition, other PLS-DA discrimination models were established when the samples were divided into two categories (ruminant and non-ruminant).Values of sensitivity (percentage of target samples correctly classified), specificity (percentage of non-target samples correctly classified) and classification error (the average value of the mis-classified samples) were calculated for the evaluation of discriminations (Ockerman & Hansen, 1999; Abbas et al., 2009).

11For the discrimination of ruminant adulteration based on LIBS spectra, several PLS-DA models were established in the order of proportion of addition. When the adulteration ratio reached between 1% and 40%, 24 ruminant samples and 60 blended samples described in Section 2.1. were considered in the PLS-DA model. The adulterations were further separated into subsets, and more blended samples within the adulteration ratio range were added into the corresponding subsets to meet the requirements of sample size in the models. Samples were divided into calibration and validation sets by taking every fourth sample ascending in reference data into validation set, while the others comprised the calibration set. The rate of correct discrimination was calculated for the discrimination of adulterated samples. If a sample of pure non-ruminant was judged to be adulterated, it was marked as false positive; if the adulterated sample is judged as non-ruminant, it was marked as false negative. The total number of samples minus the number of false positives and false negatives was defined as the number of correctly discriminated samples (Xu et al., 2016).

3. Results

3.1. Difference analysis of elemental characteristics

12The elemental analysis clearly showed the presence of various elements in all bone samples, including C, H, O, N, S, Ca, P, Na, Mg, K, Fe, Zn, Sr, and Ba (Table 1). The mean and standard deviations (SDs) were calculated to analyze the elemental concentrations on bone fractions of different species. Upon comparing all of the elements present in the tested samples, it is observed that Ca was most abundant. Besides, the content of gadolinium (Gd) was generally low (< 0.5 ppm) and was even below the detection limit of ICP-MS.

Image 1000000000000311000001C603917C3FD36F053B.jpg

13The majority of individual elemental composition (C, N, H, Ca, Na, K, Mg, Zn, Sr, and Ba) was statistically different (< 0.05) among the tested species (Table 1). The concentrations of Sr and Ba in the ruminant (bovine and ovine) bone fractions were significantly higher than in non-ruminant samples (porcine and poultry), whereas C exhibited the reverse trend. Moreover, compared with the poultry samples, porcine bone fraction possessed distinctly higher amounts of Ca and Na and lower amounts of K and Zn. Significantly higher contents of Mg and Sr and significantly lower contents of N and H were detected in ovine bone fractions compared with bovine samples.

3.2. Species discrimination based on elemental characteristics

14In order to classify the bone fractions originating from different animal species based on the elemental characteristics, the concentrations of ten kinds of specific elements (C, N, H, Ca, Na, K, Mg, Zn, Sr, and Ba) were evaluated by PCA, which is illustrated in figure 1. In figure 1a, the first two principal components explain 41.09% and 17.17% of the total variance. Although non-ruminant and ruminant samples were nearly separated, the overlap of bovine and ovine samples were considered difficult to distinguish. In addition, the loading plot (Figure 1b) shows the correlation and contribution rates of the elements for the distributions in the score plot (Figure 1a). The distributions of poultry, mostly at the negative end of PC1 and PC2, are attributed to K and Zn, while ruminant spreads mostly along the positive direction of PC1 and is attributed to Ba, Sr, and Ca. Overall, species discrimination of PAP based on elemental characteristics of their bone fraction is feasible.

Image 100000000000031C000002F0D68FBE4101D7B069.jpg

3.3. Correlation analysis between LIBS spectra and element characteristics

15Each LIBS spectrum is an average of 126 original spectra and figure 2 displays the averaged spectrum for a typical sample of a bone fraction. According to the National Institute of Standards and Technology (NIST) atomic spectra database, these profiles contain atomic and ionic lines of C, O, N, H, Ca, P, Na, K, Mg, Sr, and Ba within the wavelength range of 190-950 nm. Emissions from the CN molecular band were observed at approximately 388.3 nm due to carbon recombination with atmospheric nitrogen (Akpovo et al., 2013).

Image 10000000000001C400000112B15DD49BB11DF69F.jpg

16Because the spectral line intensity of any element is directly proportional to its concentration in the target sample (Tripathi et al., 2015), the elemental difference between bone fraction samples can be expressed effectively by the intensity in the LIBS spectra. In order to explore the correlation between LIBS and element characteristics, the section spectrum of different bone fractions is shown in figure 3. The spectral lines of Ca are abundant; for instance, the peaks at 315.89 nm and 317.93 nm in mammalian samples (porcine, bovine and ovine) were more intense than in poultry bone fraction. Furthermore, the LIBS spectra provided a clear difference at 407.77 nm and 455.40 nm between the ruminant (bovine and ovine) and non-ruminant (porcine and poultry) samples since the contents of Sr and Ba in the ruminants were significantly higher. Since porcine bone fractions exhibited higher amounts of Na among the non-ruminant samples, the intensity at 589.00 nm and 589.59 nm were higher than in poultry samples. In addition, the peaks at 279.55 nm, 280.27 nm and 285.21 nm in ovine samples were more intense than the ones in poultry samples. Whereas, the peaks at 766.49 nm and 769.9 nm in ovine samples presented the opposite tendency. It is indicated that Mg and K may contribute to the differences.

Image 100000000000031B0000031DC4AB26BF638E1052.jpg

3.4. Species discrimination based on LIBS spectral characteristics

17The broadband LIBS spectra consist of 12,990 intensity channels ranging from 190 nm to 950 nm, and each channel was used as an input variable in the PCA and PLS-DA model. As shown in figure 1c, the variation between poultry and ruminant samples is expressed by PC1. The loading plot (Figure 1d) indicates high concentrations of Ca in the ruminant samples compared to poultry samples. Meanwhile, PC2 placed the porcine samples on the positive side and poultry samples on negative side. The distributions of porcine, significantly at the positive end of PC2, are mostly attributed to Na (Figure 1e). In addition, bovine and ovine samples were clustered in figure 1c, which indicated higher discrimination power of LIBS profiles than that of element profile (Figure 1a).

18To confirm the obtained separation, PLS-DA discrimination models were then established based on the whole LIBS spectra and selected high-marked spectra. Table 2 shows the PLS-DA discrimination results, including the values of sensitivity, specificity and classification error, which were determined via internal cross-validation (leave one out). Based on whole LIBS spectra, discrimination 1 indicated a clear separation between porcine and poultry bone fractions compared to the remaining samples for which the sensitivity, specificity and classification error were 1, 1 and 0, respectively, whereas the discrimination values of the ovine or bovine samples were not optimal. This result is very similar to the groupings observed in figure 1. Moreover, discrimination 2 (whole spectra) presented an ideal situation with a perfect diagnostic classification of the ruminant and non-ruminant samples, leading to 100% discrimination without any exception.

Image 100000000000031100000137344BC6CE8649DA04.jpg

19Because the majority of the variables in the whole spectra PLS-DA model may not significantly contribute to the differences between species, down-selecting the variables that were used as inputs into the PLS-DA model should produce a more efficient and robust model (De Lucia & Gottfried, 2011). After a spectral peak search resulting from the LIBS emission, genetic algorithms (GA), which were applied successfully in previous papers (Leardi & Gonzalez, 1998), were used to select the most informative spectra in this study. The wavelength and matched elemental information of high-marked variables were selected from whole LIBS spectra and are shown in table 3.

Image 100000000000017A000002970E20B10A5290E012.jpg

20In table 2, discrimination 1 (high-marked spectra) shows that terrestrial animal species present relatively good values of sensitivity and specificity, which all exceeded 0.9 and were close to 1, and lower classification error (close to 0), which indicates a good classification of the bone fractions according to their animal origin. Moreover, discrimination 2 (high-marked spectra) works as well as the whole spectra PLS-DA model, which can satisfy the demand of discrimination.

3.5. Detection of ruminant-derived components in PAPs based on LIBS spectral characteristics

21LIBS spectra of the bone fraction separated from raw non-ruminant terrestrial PAPs and adulterated samples (1%–40%) were subjected to the PLS-DA algorithm. The calibration model was established using cross-validation and independent validation was predicted to assess model accuracy. The detection limits for ruminant adulteration were explored. Results of calibration indicated that correct discrimination rates of ruminant adulteration are both higher than 92%, with several false positive and false negative samples. Getting rid of the adulterated samples of 1% ruminant in non-ruminant samples, PLS-DA discriminant models were re-established for the adulteration percentage range of 5%-40%, but the result of independent validation was not very satisfactory with the correct rate rising to 85.71%. For adulteration percentage range of 10%-40%, results of calibration showed that correct discrimination rate was 100%, with none false positive and false negative sample. In addition, good validation results were acquired with only one false negative sample in figure 4 and the correct discrimination rate was about 95%. Furthermore, results of three groups for different adulteration ratio in table 4 indicated that lower concentration samples were more likely to be misclassified. It is concluded that LIBS can be used to detect the ruminant-derived components in PAPs.

Image 100000000000017F000001EE476E5C854A31ABDE.jpg

Image 1000000000000310000000CEA1506B02D8A24B1A.jpg

4. Discussion

22The results of previous experiments showed that the element information of raw PAP in different samples of terrestrial species was different mainly due to the uncertainty of the proportion of fresh bone. Therefore, elemental analysis focusing on the bone fraction issued from terrestrial PAP was conducted in this study. After bone fraction extraction, real PAP samples and self-manufactured ones of the same species show no significant difference in elemental profile as well as LIBS spectra.

23The organic contents of C and H were relatively low and the mineral contents of Ca, P, and Mg were greater in this study compared with the existing results of the elemental determination of PAP (Cascarosa et al., 2012), which may be attributed to bone fraction extraction from PAP. The concentrations of Sr and Ba in ruminants were significantly higher, which is probably because of grazing diet and differences in gastrointestinal tracts just as the enrichment of Sr/Ca and Ba/Ca ratios in ruminant fossil bone has been elucidated in geochemistry (Domingo & Grimes, 2012). The difference analysis of elemental characteristics reveals a high potential for species discrimination based on elemental characteristics.

24Combined with multivariate data analysis (PCA and PLS-DA), LIBS were successfully applied to determinate ruminants. Furthermore, the discrimination of high-marked spectra presented a relatively better result compared to whole spectra, with sensitivity and specificity both above 0.9. This phenomenon illustrated that variables from high-marked spectra enhance their contribution to the classification of the whole LIBS spectra and helped in the differentiation into the different species. Significant differences in samples from different species were revealed for ten different elements (C, N, H, Ca, Na, K, Mg, Zn, Sr, and Ba), while high-marked spectra only involved six of them (Ca, Na, Mg, K, Sr, and Ba). The main reasons are as follows:

25– none of the emission signals of Zn were detected under our spectral conditions;

26– the species differences for the C and N spectral line intensities were inconsistent with the results of the elemental analysis due to the reaction of C + N2 ↔ CN + N (Dong et al., 2011);

27– although there was an extremely low content in the samples, Gd may affect the spectral peak of 656.36 nm, which has been identified as H I (656.28 nm) and results from the potential existence of Gd I (656.48 nm). Compared with the analytical results of the elemental composition differences from different species, the LIBS spectral characteristics performed similarly, which revealed the mechanism of species discrimination based on the elemental LIBS characteristics.

28By increasing the number of dots and the disk area, the discrimination power of the method may be further improved theoretically. Relying greatly on the elemental information of PAPs, the method is only employed for the species discrimination of the feedstock nowadays. This study attempts to explore new methods based on bone fraction and is the basis for future research on combination techniques based on different components of PAPs. Compound feeds with mineral ingredients and additives may have large interferences on this method due to variations in elemental composition.

5. Conclusions

29In this study, the different kinds of bone fractions separated from PAP samples presented clearly diverse LIBS elemental characteristics. It is indicated that PLS-DA model based on high-marked LIBS spectra was satisfactorily applied to differentiate the tested species, including 21 wavelength points related to six elements (Ca, Na, Mg, K, Sr, and Ba) selected by GA. For discriminant analysis of ruminant-derived components in PAPs, the correct rate to detect 10%-40% adulteration was about 95%. Given that LIBS can effectively analyze the elemental specificity of terrestrial PAPs, it may be considered as a promising analytical methodology for its discrimination into the animal species or groups from which it originates.

Acknowledgements

30This research was supported by National Key R&D Program of China (2017YFE0115400) and National Key Research and Development Program of China (No. 2016YFE0112800).

Bibliographie

Bibliography

Abbas O. et al., 2009. Assessment of the discrimination of animal fat by FT-Raman spectroscopy. J. Mol. Struct., 924, 294-300.

Akpovo C.A. et al., 2013. Regional discrimination of oysters using laser-induced breakdown spectroscopy. Anal. Methods, 5(16), 3956.

Bilge G. et al., 2016a. Determination of whey adulteration in milk powder by using laser induced breakdown spectroscopy. Food Chem., 212, 183-188.

Bilge G. et al., 2016b. Identification of meat species by using laser-induced breakdown spectroscopy. Meat Sci., 119, 118-122.

Bodwell C.E. & Anderson B.A., 1986. Nutritional composition and value of meat and meat products. San Diego, CA, USA: Academic Press, 321-369.

Cascarosa E., Gea G. & Arauzo J., 2012. Thermochemical processing of meat and bone meal: a review. Renewable Sustainable Energy Rev., 16(1), 942-957.

De Lucia F.C. & Gottfried J.L., 2011. Influence of variable selection on partial least squares discriminant analysis models for explosive residue classification. Spectrochim. Acta, Part B, 66(2), 122-128.

Domingo L. & Grimes S.T., 2012. Trace element analyses indicative of paleodiets in Middle Miocene mammals from the Somosaguas site (Madrid, Spain). Geol. Acta, 10(3), 239-247.

Dong M. et al., 2011. Experimental study on the characteristics of molecular emission spectroscopy for the analysis of solid materials containing C and N. Opt. Express, 19(18), 17021-17029.

Forni O. et al., 2013. Independent component analysis classification of laser induced breakdown spectroscopy spectra. Spectrochim. Acta, Part B, 86, 31-41.

Fumière O. et al., 2009. Methods of detection, species identification and quantification of processed animal proteins in feedingstuffs. Biotechnol. Agron. Soc. Environ., 13(S), 59-70.

Gao F. et al., 2017. A novel FT-IR spectroscopic method based on lipid characteristics for qualitative and quantitative analysis of animal-derived feedstuff adulterated with ruminant ingredients. Food Chem., 237, 342-349.

Gao F. et al., 2018. Analytical raman spectroscopic study for discriminant analysis of different animal-derived feedstuff: understanding the high correlation between raman spectroscopy and lipid characteristics. Food Chem., 240, 989-996.

Georgievskii V.I., Annenkov B.N. & Samokhin V.T., 1981. Mineral composition of bodies and tissues of animals. In: Mineral nutrition of animals. Sevenoaks, UK: Butterworth & Co., 69-77.

Gottfried J.L., Harmon R.S., De Lucia F.C. & Miziolek A.W., 2009. Multivariate analysis of laser-induced breakdown spectroscopy chemical signatures for geomaterial classification. Spectrochim. Acta, Part B, 64(10), 1009-1019.

Kaiser J. et al., 2012. Trace elemental analysis by laser-induced breakdown spectroscopy—Biological applications. Surf. Sci. Rep., 67(11-12), 233-243.

Leardi R. & Gonzalez A.L., 1998. Genetic algorithms applied to feature selection in PLS regression how and when to use them. Chemom. Intell. Lab. Syst., 41(2), 195-207.

Lecrenier M.C. et al., 2016. Identification of specific bovine blood biomarkers with a non-targeted approach using HPLC ESI tandem mass spectrometry. Food Chem., 213, 417-424.

Miziolek A.W., Palleschi V. & Schechter I., 2006. Laser-induced breakdown spectroscopy fundamentals and applications. New York, NY, USA: Cambridge University Press.

Moncayo S. et al., 2016. Classification of red wine based on its protected designation of origin (PDO) using laser-induced breakdown spectroscopy (LIBS). Talanta, 158, 185-191.

Ockerman H.W. & Hansen C.L., 1999. Animal by-product processing & utilization. Boca Raton, FL, USA: CRC Press.

Oztoprak B.G. et al., 2012. Analysis and classification of heterogeneous kidney stones using laser-induced breakdown spectroscopy (LIBS). Appl. Spectrosc., 66(11), 1353-1361.

Sirven J.-B. et al., 2007. Feasibility study of rock identification at the surface of Mars by remote laser-induced breakdown spectroscopy and three chemometric methods. J. Anal. At. Spectrom., 22(12), 1471.

Tena N. et al., 2014. Differentiation of meat and bone meal from fishmeal by near-infrared spectroscopy: extension of scope to defatted samples. Food Control, 43, 155-162.

Tian Y. et al., 2014. Comparative investigation of partial least squares discriminant analysis and support vector machines for geological cuttings identification using laser-induced breakdown spectroscopy. Spectrochim. Acta, Part B, 102, 52-57.

Tripathi D.K. et al., 2015. An efficient approach of laser induced breakdown spectroscopy (LIBS) and ICAP-AES to detect the elemental profile of Ocimum L. species. Biocatal. Agric. Biotechnol., 4(4), 471-479.

Xu L. et al., 2016. Discriminant analysis of terrestrial animal fat and oil adulteration in fish oil by infrared spectroscopy. Int. J. Agric. Biol. Eng., 9(3), 179-185.

Yajie L.I. et al., 2017. Production and properties of four kinds of nano-sized bone products. Food Sci., 38(5), 38-44.

Yu K.Q., Zhao Y.R., Liu F. & He Y., 2016. Laser-induced breakdown spectroscopy coupled with multivariate chemometrics for variety discrimination of soil. Sci. Rep., 6, 27574.

To cite this article

Mengyan Wang, Lujia Han, Zengling Yang & Xian Liu, «Species discrimination of terrestrial processed animal proteins by laser-induced breakdown spectroscopy (LIBS) based on elemental characteristics», BASE [En ligne], Volume 23 (2019), Numéro 3, 137-146 URL : https://popups.ulg.ac.be/1780-4507/index.php?id=17945.

About: Mengyan Wang

College of Engineering. China Agricultural University (East Campus). P.O. Box 191. 17 Qing-Hua-Dong-Lu. Hai-Dian District. Beijing 100083 (PR China).

About: Lujia Han

College of Engineering. China Agricultural University (East Campus). P.O. Box 191. 17 Qing-Hua-Dong-Lu. Hai-Dian District. Beijing 100083 (PR China).

About: Zengling Yang

College of Engineering. China Agricultural University (East Campus). P.O. Box 191. 17 Qing-Hua-Dong-Lu. Hai-Dian District. Beijing 100083 (PR China).

About: Xian Liu